Category index
Guards & Safety
8 documented faults under Guards & Safety. Each entry sets out the symptom as owners report it, the most likely cause, the checks that confirm or rule it out, and whether the repair is worth doing — compiled and cross-checked from manufacturer documentation and owner reports, with sources listed on every page.
Documented faults
- Einhell GE-PH 2555 A
The cutting blades keep moving after you let go of the throttle lever, instead of coming to a complete stop at idle
The carburettor's idling speed is set too high — Einhell's manual ties this exact symptom directly to the idle-speed setting, without specifying the drive mechanism involved
Guards & Safety 2026-11-02 - Einhell TC-AG 115/750
The angle grinder won't start after a power cut or an unplug/replug, even though the switch is pressed and locked in the On position
Einhell's restart safeguard — a deliberate safety feature that keeps the grinder off after any power interruption while the switch was left locked on, by design, not a fault
Guards & Safety 2026-11-02 - Einhell GC-CH 18/40 Li
The hedge trimmer won't run, or the cutters stop the moment you shift your grip, even though the battery shows charge
Almost always the two-handed safety switch — Einhell's design requires both handle switches held down together, and releasing either one stops the cutters instantly — followed by a jammed blade or a battery that isn't seated, charged, or (rarely) genuinely defective
Guards & Safety 2026-10-13 - Einhell GP-LC 36/40 Li BL
The chainsaw won't run at all when the trigger's pulled, or it starts then cuts in and out
Most often the chain brake (front hand guard) is tripped so the saw refuses to run at all, or the battery isn't making contact — both free checks. If it starts but cuts in and out, Einhell's own table routes every cause of that straight to a workshop, with no user-level fix given
Guards & Safety 2026-10-12 - Triton TWX7RT001
The router table module has no function at all when switched on — nothing happens
Almost always the Workcentre's own safety switchbox, which Triton's manual confirms resets itself to OFF the instant power is lost and has to be switched back on manually, or the router's own separate power switch being left off underneath the table — not a fault with the module itself
Guards & Safety 2026-10-12 - Record Power PT260
The PT260 won't start at all — the motor doesn't run when the switch is pressed, in either planing or thicknessing mode
One of the PT260's three safety microswitches isn't being closed by the table lock, the dust extraction hood, or the swing-over outlet — the interlock working as designed, not a fault
Guards & Safety 2026-09-15 - Makita UC4041A
The saw chain keeps moving even after the chain brake lever has been engaged
Worn brake band inside the clutch drum, which no longer grips hard enough to stop the chain when the brake is applied
Guards & Safety 2026-09-07 - Makita 5704R
Circular saw's lower blade guard returns slowly after a cut, hangs partway, or has to be flicked shut by hand
Resin and compacted sawdust in the guard's pivot ring binding its rotation — occasionally a stretched or detached return spring
Guards & Safety 2026-06-11
Other categories
Batteries & ChargingBlades & AlignmentChucks & FittingsElectronics & FirmwareMechanical & MotionMotor & DrivePumps & Pressure All categories →