The symptom pattern

The grinder was running, the power dropped out for a moment — an RCD trip, a loose extension lead, someone else unplugging the socket — and now it won’t start again. The switch is still pressed and locked forward. Nothing happens when the power comes back. It looks exactly like the kind of fault that means a trip to a repair shop, and Einhell’s own manual explains why it almost certainly isn’t.

What Einhell’s own manual says

The TC-AG 115/750 has a safety feature called a restart safeguard, and the manual states its behaviour plainly: “If the mains power supply is interrupted when the switch is locked in the On position, the electric tool will not run after the power supply is restored. For the equipment to run, the switch must be turned off and then on again.” That’s the entire mechanism — the grinder is refusing to spring back to life on its own after any power loss while locked on, specifically so it can’t restart unexpectedly while unattended.

The switch itself is a two-stage action, and the manual spells out both directions: “To switch on, press down the On/Off switch (2) at the back, push it forwards and then press it down at the front. To switch off the angle grinder, depress the On/Off switch (2) at the back. The On/Off switch (2) will jump back into its starting position.” Skipping any one of those three motions on restart won’t start the tool and can easily be mistaken for the grinder itself being dead.

Two other things the manual names explicitly are not owner repairs. A damaged power cable “must be replaced by the manufacturer or its after-sales service or similarly trained personnel.” And a motor that’s sparking heavily during use points at worn carbon brushes, which the manual says should only be checked and replaced “by a qualified electrician” — unlike some grinders where a brush swap is a straightforward DIY job, this one is explicit that it isn’t.

Working through it

Start by fully switching the grinder off — depress the back of the switch and let it spring back to its rest position — then go through the complete start sequence again: back, forward, front. That resolves the restart safeguard condition in seconds and costs nothing. If it still won’t run at all after that, check the lead for obvious damage without opening anything up; a damaged cable needs replacing by a qualified person, not a DIY splice. If the grinder runs but throws noticeably more sparks from the motor housing than it used to, that’s the brushes, and Einhell’s manual is clear that’s also not a parts-and-screwdriver job on this model.

Verdict

Nearly always a free, immediate fix and not really a fault: the restart safeguard doing its job after a power interruption, cleared by switching fully off and restarting properly. The two things that are genuine faults — a damaged cable or worn carbon brushes — both get routed by Einhell’s own manual to a qualified electrician or authorised service rather than an owner-level repair, so there’s nothing to buy or attempt at home for either of those; the grinder itself isn’t written off, just handed to someone qualified to open the motor housing.